Laminar airflow ceilings2025-10-13T12:04:30+02:00

AIRFLOW CEILINGS

Laminar Airflow Ceilings

LAMINAR AIRFLOW CEILINGS

Combating Airborne Contamination

The presence of airborne particles and bio-contaminants (bacteria, fungi, viruses, etc.) is a major challenge for both industrial and medical environments.

Installing efficient filtration systems is essential to control and prevent contamination.

The concept of localized protection refers to equipment installed as close as possible to the critical area  whether in a polluted industrial environment or a cleanroom setting.

Solution de protection rapprochée

Localized Protection Solutions

Since 1989, Euroflux has been designing and manufacturing in France high-performance equipment for controlling particulate and airborne bio-contamination.

Our Laminar Airflow Ceilings are part of these localized protection solutions.

They are designed to protect work areas from surrounding contamination.

Our standard and custom-built solutions meet your specific spatial and technical requirements while complying with ISO 14644 standards.

From project design to installation and commissioning, you benefit from a dedicated point of contact throughout the entire process.

OUR RANGE OF MODULAR FILTER CEILINGS

Laminar Airflow Ceiling

Full coverage with MODUL’AIR or MODUL’AIR EXTLAT units available in fixed, mobile, or suspended structures.
Includes airflow guidance system, integrated lighting, and electrical control cabinet.

Turbulent Airflow Ceiling

Partial coverage using MODUL’AIR, MODUL’AIR EXTLAT, or FFU units available in fixed, mobile, or suspended versions.
Includes airflow guidance, integrated lighting, and electrical control cabinet.

Picto modulair Euroflux

Custom Airflow Ceiling

Motorized gantry for adjustable airflow direction, inactinic light solutions for electronic applications, full blackout versions for laser processes, or large-scale configurations all tailored to your specific needs.

Durability, Modularity & Energy Optimization

For over 35 years, our mission has been to design and manufacture in France both standard and custom solutions with a low environmental impact.
We place great emphasis on the durability, modularity, and energy efficiency of our equipment.
The innovative design of our Laminar Airflow Ceilings guarantees long-term Emery test compliance and performance stability.
Our technical teams rigorously adhere to all applicable standards and regulations.

Durability, Modularity & Energy Optimization

For over 35 years, our mission has been to design and manufacture in France both standard and custom solutions with a low environmental impact.

We place great emphasis on the durability, modularity, and energy efficiency of our equipment.

The innovative design of our Laminar Airflow Ceilings guarantees long-term Emery test compliance and performance stability.

Our technical teams rigorously adhere to all applicable standards and regulations.

Discover Our Range of Modular and Adaptable Solutions

Laminar Airflow Ceiling

Turbulent Airflow Ceiling

Custom Airflow Ceiling

THE ADVANTAGES OF OUR LAMINAR AIRFLOW CEILINGS

THE ADVANTAGES OF OUR LAMINAR AIRFLOW CEILINGS

Our Laminar Airflow Ceilings are designed and manufactured by Euroflux in France, ensuring high energy efficiency and superior air cleanliness.

  • Easy Filter Access: G4 prefilter on the side, H14 access from below or the side depending on the model.
  • Long-Term Reliability Emery Test Approved: Guaranteed static and dynamic airtightness.
  • Laminar Flow Control: Integrated electronics with manual or automated control (0–10V or Modbus).

SIX KEY COMPONENTS

  • Chassis
    Allows the assembly of multiple MODUL’AIR units, as well as the installation of support posts, threaded rods, or airflow guides.
  • Airflow Guidance
    Flexible guidance with strip curtains, or rigid guidance using panels (Plexiglas, stainless steel, etc.). Can also integrate with machine enclosures.
  • Absolute Filter
    Standard: H14 / Optional: U15 to U17
  • Plenum
    Ensures even air distribution upstream of the HEPA filter for a uniform laminar airflow.
  • Prefiltration
    Standard: G4 prefilter / Optional: M5 to F9
  • Ventilation
    High-efficiency EC motor-fan (ERP 2015 compliant) with integrated electronics. Available with manual or self-regulated control (0–10V or Modbus signal).

Discover Our Range of Modular and Adaptable Solutions

Laminar Airflow Ceiling

Turbulent Airflow Ceiling

Custom Airflow Ceiling

THE ADVANTAGES OF OUR LAMINAR AIRFLOW CEILINGS

THE ADVANTAGES OF OUR LAMINAR AIRFLOW CEILINGS

Our Laminar Airflow Ceilings are designed and manufactured by Euroflux in France, ensuring high energy efficiency and superior air cleanliness.

  • Easy Filter Access: G4 prefilter on the side, H14 access from below or the side depending on the model.
  • Long-Term Reliability Emery Test Approved: Guaranteed static and dynamic airtightness.
  • Laminar Flow Control: Integrated electronics with manual or automated control (0–10V or Modbus).

SIX KEY COMPONENTS

  • Chassis
    Allows the assembly of multiple MODUL’AIR units, as well as the installation of support posts, threaded rods, or airflow guides.
  • Airflow Guidance
    Flexible guidance with strip curtains, or rigid guidance using panels (Plexiglas, stainless steel, etc.). Can also integrate with machine enclosures.
  • Absolute Filter
    Standard: H14 / Optional: U15 to U17
  • Plenum
    Ensures even air distribution upstream of the HEPA filter for a uniform laminar airflow.
  • Prefiltration
    Standard: G4 prefilter / Optional: M5 to F9
  • Ventilation
    High-efficiency EC motor-fan (ERP 2015 compliant) with integrated electronics. Available with manual or self-regulated control (0–10V or Modbus signal).

Technical specifications

  • Structure: 100% stainless steel 304L
  • Absolute filter protection grille
  • Quick interconnection between multiple MODUL’AIR units
  • Self-regulating EC fan
  • G4 prefilter
  • H14 absolute filter
  • H14 maintenance access from below
  • Structure: 100% stainless steel 304L
  • Absolute filter protection grille
  • Quick interconnection between multiple units
  • Self-regulating EC fan
  • G4 prefilter
  • H14 absolute filter
  • H14 maintenance access from the side
  • Structure: aluminium
  • G4 prefilter
  • H14 filter
  • EC fan
  • H14 maintenance access from the top

Technical specifications

  • Structure: 100% stainless steel 304L
  • Absolute filter protection grille
  • Quick interconnection between multiple MODUL’AIR units
  • Self-regulating EC fan
  • G4 prefilter
  • H14 absolute filter
  • H14 maintenance access from below
  • Structure: 100% stainless steel 304L
  • Absolute filter protection grille
  • Quick interconnection between multiple units
  • Self-regulating EC fan
  • G4 prefilter
  • H14 absolute filter
  • H14 maintenance access from the side
  • Structure: aluminium
  • G4 prefilter
  • H14 filter
  • EC fan
  • H14 maintenance access from the top

The key stages of your project

1.
Feasibility Study

2.
Design

3.
Installation

4.
Validation

5.
4.0 Monitoring & Maintenance

Our Laminar Airflow Ceiling serve the following sectors

Our Laminar Airflow Ceiling serve the following sectors

Our Laminar Airflow Ceiling serve the following sectors

CONTACT US



    Aller en haut